4.
Construct the device file name for each device, using the device information, and enter the file
names in your table. Use the following formula to construct the device file name:
cxtydz
where:
x = SCSI bus instance number
y = SCSI target ID
z = LUN
c stands for controller
t stands for target ID
d stands for device
The numbers x, y, and z are hexadecimal.
Table 4 Device file name example
SCSI bus instance
number
00
00
5.
Verify that the SCSI TIDs correspond to the assigned port address for all connected ports (see
mapping tables in
properly.
If the logical devices are not recognized properly:
Check the AL-PA for each port using the LUN Manager software.
If the same port address is set for multiple ports on the same loop (AL with HUB), all port ad-
dresses except one changed to another value, and the relationship between AL-PA and TID
does not correspond to the mapping given in
for each port, reboot the server, and then verify new device recognition again.
If unused device information remains, the TID-to-AL-PA mapping will not correspond to the
mapping given in
new device recognition again.

Configuring disk array devices

Disk arrays are configured using the same procedure for configuring any new disk on the host. This
includes the following procedures:
1.
Verifying the device files and drivers
2.
Creating the device files
3.
Creating the physical volumes
4.
Creating new volume groups
5.
Creating logical volumes
6.
Creating the file systems
7.
Setting the I/O timeout parameter
8.
Creating the mount directories
Hardware path
14/12.6.0
14/12.6.1
Appendix B
on page 37, for values). If so, the logical devices are recognized
Appendix B
on page 37. Renew the device information, and then verify
SCSI TID
LUN
6
0
6
2
Appendix B
on page 37, set a different address
XP Disk Array Configuration Guide for HP-UX
File name
c6t0d0
c6t0d1
17