Model 800-048 series "a" 2 150 psi (150 bar) operating pressure 2250psi (155 bar) maximum working pressure

Advertisement

Quick Links

This manual
contains
IMPORTANT
WWARNINOS
and
INSTRUCTIONS
READ
AND
RETAIN FOR REFERENCE
MODEL 800-048 SERIES "A"
2 150 psi (150 bar) OPERATING PRESSURE
2250psi (155 bar) MAXIMUM WORKING PRESSURE

Advertisement

Table of Contents
loading

Summary of Contents for Graco Hydra-Clean 2104ES

  • Page 1 This manual IMPORTANT contains WWARNINOS INSTRUCTIONS READ RETAIN FOR REFERENCE MODEL 800-048 SERIES "A" 2 150 psi (150 bar) OPERATING PRESSURE 2250psi (155 bar) MAXIMUM WORKING PRESSURE...
  • Page 2 ~NJECTOQIM HAZARD Do not use chemicals or agents which are not compatible with Buna-N and PVC or neoprene cover of hose. Fluids under high pressure from spray or leaks can penetrate the skin and cause extremely serious Do not leave a pressurized unit unattended. Shut off injury, including the need for amputation.
  • Page 3: Installation

    INSTALLATION For removing rust andold paint we recommend using Check Electrical Service and Plug Before plugging in the sprayer, be sure the electrical a water sandblaster. Accessoriesand instruction V, 60 manual 801.190 for installation and operation. service is 1 phase 220 H A C , Amp.
  • Page 4: Operation

    CAUTION OPERATION spraying. for longer pump life. The pump will Startup overheat if left running for over minutes Before starting, be sure to read the safety warnings and setup instructions. Check the filter screen the water inlet connection Turn on the water supply. as often as necessary, at least daily.
  • Page 5 Water in pump crankcase. M a y be caused by humid air Change oil at month or hour interval condensing into water inside the using Graco Crankcase (other approved P.N. 801-144. crankcase. every month or hours) Frequent or premature Scored plungers.
  • Page 6 SOLUTION Check, replace. building circuit fuse blown. Unplug power cord'. decrease pressure Overload switch has opened. Check, replace. Power cord unplugged, or Electric motor stops while building circuit fuse blown. spraying. Unplug powei cord'. relieve pressure-allow Overload breaker.has opened. to cool. DonZ use more than loOftoi ga extension cord.
  • Page 7 Plungers Photo 4. M1 1 w r e n c h , 1 ) U s i n g . a n remove the plunger retainer. 2) Slide out the seal retainer w i t h oil wick and rubber barrier slinger.
  • Page 8 801-457 "....
  • Page 9: Parts List

    Ref. No. 50 Includes items 51-66, 79 & f j / 7 g PART DESCRIPTION N O . NO. 801 -082 SCREW, machine. hex hd, r ! A 801-081 CREW. machine, hex hd. 801 -023 WASHER. flat. 801 -01 5 5/16 WASHER.
  • Page 10: Electrical Schematic

    PARTS LIST (continued) ELECTRICAL SCHEMATIC REF PART D.ESCRlPTlON NO. NO. 77-90 Items are pump internal replacement parts. See exploded view of pump for details. ~ n l - n n ". . _. .. C A P ". 801.028 O-RING, cap 801-267 DISCHARGE MANIFOLD...
  • Page 11 Kit 801 -083 Repair A, B. C, Includes items / A ) PARTS LIST PART DESCRIPTION N< 801 -007 SPRAY HOSE, 3/8" ID, (1 5 m) 800-043 SPRAY GUN, (replaceable parts include items 3-18) SERVICE HANDLE ACCESS PLATE 1. Pressaccesspin(17)fromgunhandleandremove SPRING access plate ( 4 ) by sliding plate towards back TRIGGER...
  • Page 12: Technical Data

    This warranty is conditioned upon the prepaid return of the equipment clatmed to be defective for examination by Graco toverify the claimeddefect. If the claimed defect is verified. Graco will repair or replace free of charge. any defective parts. The equipment will be returned the original purchaser transportation prepaid.