1.2.5 Electrical Specifications

Specification
Rated voltage
Input voltage range
Rated frequency range
Input frequency range
Rated current
Power consumption
Insulation resistance
Dielectric strength

1.2.6 Environmental Conditions

Table 1-9. Acceptable Environmental Conditions

Condition
Temperature
Humidity
Shock resistance
Vibration resistance
*1 : For printer operation, conditions must be in the range shown in the figure below.
*2
: These conditions are applicable when the printer is in its shipping container.
*3
: Without condensation.
Humidity
(% RH)
80%
55%
20%

Figure 1-5. Temperature/Humidity of Range

Rev. A

Table 1-8. Rated Electrical Ranges

120 V Version
120 VAC
132 V
103.5
60 Hz
50
49.5
60.5 Hz
0.5 A
Approx. 15 W
(self-test with 10-cpi LQ characters)
minimum
10 M
(applying 500 VDC between AC
line and chassis)
1000 VAC rms for 1 minute or
1200 VAC rms for 1 second
(between AC line and chassis)
Operating
10
35 C (50
20
80% RH
1G (within 1 msec.)
0.15 G
10
220 - 240 V Version
220 - 240 VAC
49.5
(self-test with 10-cpi LQ characters)
10 M , minimum
(applying 500 VDC between AC line
1500 VAC rms for 1 minute
(between AC line and chassis)
Non Operating
*1
95 F)
20
60 C ( 4
*1, 3
5
2G (within 2 msec.)
Guaranteed Range
(Degrees)
27
35
Product Description
264 V
198
60 Hz
50
60.5 Hz
0.3 A
Approx. 15 W
and chassis)
*2
122 F)
*2, 3
85% RH
*2
*2
0.50 G
1-7