3.2.2 C199 MAIN Control Board and ASF Sensor Removal
1.
Remove the upper case (see Section 3.2.1).
2.
Remove 4CBB (M3 6) screws attaching the shield frame to the C160 MAIN Board.
3.
Remove 7 connectors (CN1, CN8, CN7, CN4, CN3, CN5, CN6) on the main board. (Push CN6 down to
release cable on main board.) Then remove the C199 Main Control Board.
4.
Remove a CBB (M3x6) screw fixing a ASF Sensor holder to printer mechanism.
When you replace the C199 MAIN Board, reset the EEPROM and perform the required
adjustments. (See Chapter 4.)
C1 99 Main B oa rd
Rev. A
CAUTION
CBB(M3 x6)
CBB(M3x 6)
Shield Plate
C N 3
C N 4
C N 1
Figure 3-2. C199 Main Board Removal
CBB(M3x6)
ASF Sensor Holder
Figure 3-3. ASF Sensor Removal
Disassembly and Assembly
CBB(M3x6)
CBB(M3x 6)
C N 5
C N 7
C N 6
C N 8
C N 9
C160 PSB/PSE Board
3-3