Error tone beeps
Cause 1:
Operation procedure is incorrect.
Measure:
Depress the [C] key to clear the error, then check the operation procedure you attempted.
Cause 2:
Control Lock position is incorrect.
Measure:
Turn the Control Lock to the correct position using the Control Key.
Cause 3:
Operation in the REG position was attempted while the drawer remained open. (In case that the Drawer-
close Compulsory Option has been selected.) (Chapter "22. System Option Setting", Address 16 - Bit
1 on page 134)
Measure:
Close the drawer, then depress the [C] key.
7. Trouble in the REG Position
Operations in the REG position cannot be carried out.
Cause 1:
Control Lock is not in the REG position.
Measure:
Turn the Control Lock to the REG position using the Control Key.
Cause 2:
Cashier Identifying Operation was not performed when the Cashier Identifying Option has been selected.
(Chapter "22. System Option Setting", Address 2 - Bit 8 on page 120)
Measure:
Perform the sign-ON or depress the Cashier Key. (Refer to page 36.)
Cause 3:
Operation was attempted while the drawer remained open. (In case that the Drawer-close Compulsory
Option has been selected.) (Chapter "22. System Option Setting", Address 16 - Bit 1 on page 134)
Measure:
Close the drawer, then depress the [C] key.
8. Trouble in the SET Position
Operations in the SET position cannot be carried out.
Cause 1:
Control Lock is not in the SET position.
Measure:
Turn the Control Lock to the SET position using the Control Key.
Cause 2:
Condition for the programming is not satisfied.
Measure:
Check the condition for the programming .
Cause 3:
Operation procedure is incorrect.
Measure:
Check the operation procedure you attempted.