Step 6. Connecting Gas Line; Control Compartment Access - Superior SDVPF-N-B Installation Instructions Manual

Sdvst direct-vent gas fireplaces
Hide thumbs Also See for SDVPF-N-B:
Table of Contents

Advertisement

Step 6. CONNECTING GAS LINE

All codes require a shut-off valve mounted in
the supply line. The orientation of the shut-off
valve should face the front. Figure 47 illustrates
two methods for connecting the gas supply.
A Sediment Trap is recommended to prevent
moisture and debris in gas line from damaging
the valve.
The flex-line method is acceptable in the U.S.A.
where local codes permit, however, Canadian
requirements vary depending on locality. Instal-
lation must be in compliance with local codes.
These appliances are equipped with a gas flex-
line for use in connecting the unit to the gas
line. See Figure 47 for flex-line description.
The flex-line is rated for both natural gas and
propane gas. A manual shut off valve is also
provided with the flex-line.
The gas control valve is located in the lower
control compartment.
Access the valve compartment by removing
the lower control compartment panel (see
Figure 49).
The incoming gas line should be piped into the
valve compartment and connected (see Figures
47 and 48). The millivolt control valve has a 3/8"
(10 mm) NPT thread inlet port. The electronic
control valve has a 1/2" (13 mm) NPT thread
inlet port and is fitted with a 1/2" x 3/8" (13 mm x
10 mm) NPT fitting.
Secure all joints tightly using appropriate
tools and sealing compounds (ensure propane
resistant compounds are used in propane ap-
plications). It is recommended to seal around
the gas line to prevent cold air leakage.
Gas line connection may be performed largely
outside of the confines of the control compart-
ment and without having to enter the firebox
behind the glass. Proceed as follows:
Acquire the shut-off valve and gas lex line and
pull the assembly forward out of the compart-
ment. Separate the shut-off valve from the gas
flex-line. Determine the length of pipe needed
to route the gas line from the last fitting (shown
in Figure 13 on Page 12) to a point within the
control compartment that will allow the shut-
off valve to be easily attached by hand to the
gas flex-line.
Using pipe-dressing materials appropriate for
the gas type, securely affix the shut-off valve
to this determined pipe length at a convenient
location outside of the appliance lower control
compartment.
28
Gas
Valve
3/8" Nipple
3/8" Union
3/8" Close
Nipple
Gas Solid Line Connector
Figure 47
Glass Door is Above
Control Compartment
Latch for
Glass Door
Control Compartment
CONTROL COMPARTMENT ACCESS/LOUVER
(
PANEL INSTRUCTIONS
Ref. Figure 49)
NOTE: The top louvered panel and the bottom
louvered control panel door remove and install
the same way as follows:
The gas controls can be found behind the control
compartment access door.
Removing Control Compartment Door:
Open the door by gently lifting it upward until
the hook catches on both sides clear the locating
slots. Then pull door out to remove.
On millivolt systems, the piezo igniter, HI/LO
flame adjustment knob, and pilot and main gas
OFF/ON control knob are located below the glass
panel enclosure.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Gas Flex Line Connector
3/8" NPT x
1/2" x 3/8" Flare
Flare Fitting
Shut-off Valve
3/8" Flex Tubing
Gas
1/2" x 3/8"
Stub
Reducer
3/8" Shut-off Valve
OFF/PILOT/ON
(gas control knob)
HI/LO (flame height
control knob)
Optional OFF/ON
Switch Can be
Installed Here
Piezo Igniter
Access
Reinstalling Control Compartment Door:
To reinstall, insert the hook catches on each side
of the door into the corresponding slots in the
control compartment opening, then gently push
forward and slide down until it locks in place.
OPENING CONTROL
COMPARTMENT DOOR
Control Valve
Figure 49
GAS CONNECTION
Note: The gas supply line
must be installed in accor-
dance with building codes
by a qualified installer
approved and/or licensed
as required by the locality.
In the Commonwealth of
Massachusetts, installation
must be performed by a
licensed plumber or gas
fitter.
3"
Min
*Sediment
Trap
Gas Shut-Off
Valve
Gas Flex-line
Gas Valve
Figure 48
Lift the Lower Control
Compartment Door
up and pull out to
remove.
Hook Catch
Out
Up
Lower Control
Compartment Door

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdvst-n-b

Table of Contents