Fireplace Specifications - Superior MULTI-OPEN SERIES Installation Instructions Manual

Direct vent multi-open series
Hide thumbs Also See for MULTI-OPEN SERIES:
Table of Contents

Advertisement

FIREPLACE SPECIFICATIONS

CDST (See-Through)
1/2
(13)
DETAIL OF
FINISH WALL
BRACKET
24
(610)
GAS INLET
ELECTRICAL
INLETS
Figure 13
LEFT SIDE VIEW
CDPF (Peninsula)
NOTE - Unit has a factory-installed
vent seal cap and vent cover plate
(see Figures 17 and 18 on page 10)
in each flue outlet. The vent seal
cap is not shown in this figure.
24
(610)
Figure 14
LEFT SIDE VIEW
8
FINISH WALL BRACKET
(Front and back edge of unit top)
FRAMING SPACERS
(Top and Both Sides)
3
(89)
(13)
4 (102)
41
(1041)
37
(940)
3
(76)
10
(267)
FINISH WALL BRACKET
(Front, back, and left edge of unit top)
41
(1041)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
10
(254)
FLUE
(Top or Side)
40
(1019)
3
TOP VIEW
47
(1197)
CONTROL
COMPARTMENT
ACCESS PANEL
FRONT VIEW
10
(254)
FLUE
(Top or Side)
40
(1019)
3
TOP VIEW
43
(1108)
(13)
2
(63.5)
CONTROL COMPARTMENT
ACCESS PANEL
FRONT VIEW
12 (305)
NOTE - Unit has a factory-installed
vent sea cap and vent cover plate
(see Figures 17 and 18 on page 10)
in each flue outlet. The vent seal
cap is not shown in this figure.
(16)
Stepped to Accept Drywall on All 4 Corners
(89)
2
(13)
(63.5)
2
(63.5)
FLUE
(Top or Side)
3 (76)
6
(175)
RIGHT SIDE VIEW
Stepped to Accept Drywall on Two Corners
FRAMING SPACERS
(Top and Side)
12 (305)
FINISH WALL BRACKET
(16)
(89)
2
(63.5)
4 (102)
37
(940)
FLUE
(Top or Side)
ELECTRICAL
INLETS
GAS INLET
3 (76)
6
(175)
12
(305)
10
(260)
ELECTRICAL
INLETS
GAS INLET
ELECTRICAL
INLETS
DETAIL OF
(13)
12
(305)
10
(260)
RIGHT SIDE VIEW

Hide quick links: