Download Print this page

Craftsman 919.195412 Owner's Manual page 21

Oil lubricated single stage horizontal portable air compressor
Hide thumbs Also See for 919.195412:

Advertisement

Available languages

Available languages

ALL MAINTENANCE AND REPAIR
OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE
TECHNICIAN.
_Risk
of Unsafe
Operation.
Unit
cycles automatically
when power
is on. When servicing, you may
be exposed to voltage sources,
compressed
air, or moving parts.
Before servicing
unit unplug or
disconnect
electrical
supply to
the air compressor,
bleed tank
of pressure,
and allow the air
compressor
to cool.
TO REPLACE
OR CLEAN
CHECK
VALVE
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air compressor
3.
Using an adjustable wrench, loos-
en outlet tube nut at air tank and
pump. Carefully move outlet tube
away from check valve.
4.
Using an adjustable wrench,
loosen pressure relief tube nut
at air tank and pressure switch.
Carefully move pressure relief tube
away from check valve.
5,
6,
Unscrew the check valve (turn
counterclockwise)
using a 7/8"
(22 mm) open end wrench. Note
the orientation for reassembly.
Using a screwdriver, carefully
push the valve disc up and down.
NOTE: The valve disc should
move freely up and down on a
spring which holds the valve disc
in the closed position; if not mov-
ing freely the check valve needs to
be cleaned or replaced.
In open
position
nothing
is
visible,
In closed
position
disc is visible.
7.
Clean or replace the check valve.
A solvent, such as paint or varnish
remover can be used to clean the
check valve.
8.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
9.
Replace the pressure release tube.
Tighten nuts.
10. Replace the outlet tube and tight-
en nuts.
11. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
21-ENG
1000003598

Advertisement

loading