Download Print this page

COZY HEDV254A Installation And Operating Instructions Manual page 4

Hi-efficient direct vent wall furnace

Advertisement

FIGURE
1
Vent Terminal
_
Air Supply Inlet
[]
Area where terminal is not permitted
VENT
TERMINAL
CLEARANCES
REFERENCELETTER TO
DRAWING
A = Clearance
above
grade,
veranda,
porch,
deck,
or
balcony
B = Clearance
to window
or door
that may be opened
C = Clearance
to permanently
closed
window
D = Vertical
clearance
to
ventilated
soffit located
above
the terminal
within
a horizontal
distance
of 2 Feet (61 cm) from
the center
line of the terminal
E = Clearance
to unventilated
soffit
F = Clearance
to outside
corner
G = Clearance
to inside corner
H = Clearance
to each
side of
center
line extended
above
meter/regulator
assembly
I = Clearance to service regulator
vent outlet
J = Clearance
to nonmechanical
air supply
inlet to building
or the
combustion
air inlet to any other
appliance
K = Clearance
to a mechanical
air supply
inlet
L = Clearance
above
paved
sidewalk
or paved
driveway
located
on public
property
M = Clearance
under veranda,
porch, deck, or balcony
CANADIAN
INSTALLATIONSI
12 Inches
(30 cm)
12 Inches
(30 cm)
12 Inches
(30 cm)
18 Inches
(46 cm)
18 Inches
(46 cm)
12 Inches
(30 cm)
12 Inches
(30 cm)
3 Feet (91 cm) within a height
15 Feet (4.5m) above
the
meter/regulator
assembly
3 Feet (91 cm)
12 Inches
(30 cm)
6 Feet (1.83 m)
7 Feet (2.13m) Avent shall
not terminate directly above
a sidewalk or paved driveway
that is located between two
single family dwellings and
serves both dwellings.
12 Inches (30 cm) permitted
only if veranda, porch, deck,
or balcony is fully open on a
minimum of two sides.
U.S. INSTALLATIONS2
12 Inches
(30 crn)
9 Inches
(23 cm)
9 Inches
(23 cm)
18 Inches
(46 cm)
18 Inches
(46 cm)
12 Inches
(30 cm)
12 Inches
(30 cm)
Clearances
are in accordance
with local
installation
codes
and
the requirements
of the gas
supplier
Clearances
are in accordance
with local
installation
codes
and
the requirements
of the gas
supplier
12 Inches
(30 cm)
3 Feet (91
cm)
above
if within
10 Feet (3 m) horizontally
Clearances
are in accordance
with local
installation
codes
and
the requirements
of the gas
supplier.
Clearances
are in accordance
with local
installation
codes
and
the requirements
of the gas
supplier.
In accordance
with the current
CSA-B149.1
Natural
Gas and Propane
Installation Code
2 In accordance
with the current
ANSI Z223.1 / NFPA 54 National
Fuel Gas Code
Page 4

Advertisement

loading

This manual is also suitable for:

Hedv253aHedv403aHedv404a