Advertisement

18900 CONDENSATE
KIT
INSTRUCTIONS
HI-EFFICIENT DIRECT-VENT WALL FURNACE
Always use this kit when the vent has a vertical ran, or where local codes prohibit draining condensate to the outside. Use
only Louisville Tin and Stove Company supplied parts. Failure to use factory supplied parts or to follow these instructions
may result in unsatisfactory perl\_rlnance, property damage, personal injury and/or loss of life.
Before beginning kit installation, open carton and identify the l\_ltowing components.
A)
c)
D)
E)
F)
P/N 18910 Condensate PanAssembly
P/N 72618 Condensate Trap Assembly
P/N 72538 3/8" Tubing
P/N 72539 3/8" Hose Clamp (2)
P/N 50606 #8 x ½" screws (2)
P/N 50053 Wing Nuts (2)
Set thermostat to "off' and allow heater to coot.
Turn off gas supply to heater.
Turn off electric power to heater.
Remove the cabinet.
Start two wing nuts onto weld pins located in the heater base. See Figure 1.
Slide the condensate pan into the bottom of the heater with slots in tabs onto the weld studs and under the wing
nuts. Use care not to rip the insulation in bottom of heater. Tighten the wing nuts to secure condensate pan.
See Figure 1.
Remove and discard the black casing plug located at center lower area of heater back.
Attach condensate trap to heater back so bottom of trap is inside the bottom of the condensate pan. Secure
using the (2) #8 screws provided. Fill trap with water. See Figure 2.
Remove and discard plastic cap from bottom of the draft inducer drain tube. See Figure 2.
Connect the tubing to the draft inducer drain tube and the condensate trap. Secure both ends with two 3/8"
hose clamps provided. See Figure 2.
Fill the condensate pan with water.
Reverse steps 4
1. Follow lighting instructions to place heater in operation.
WARNING: The water level in the condensate pan must be checked and maintained to completely cover the condensate
trap. The water provides a seal to prevent combustion products from coming through the condensate trap and entering the
living area.
"
_
Weld
Pin (2_
Condensate P,-m
Assembly
FIGURE
1
72618-
Condensate
Clmnp (2)
50606 - #8x12 Screw (2)
FIGURE
2
Page 16