Gas Connection; Installation - COZY CDV155B Installation And Operating Instructions Manual

Direct vent
Table of Contents

Advertisement

Wall Thimble
Wall Stud -_
I Inside Wall
FIGURE
7
Wall Thimble
Assembly
Outside
Wall
--Vent
Terminal Spacer Plate
Vent Terminal
GAS
CONNECTION
Make gas connection
between manual shut offvalve
and furnace valve with approved connectors.
Compounds
used on threaded joints of gas piping shall be approved for use with L.P gas. The gas lines must be checked for
leaks by the installer
with soapy water or liquid detergent,
never an open flame.
If connections
are not
exposed, a pressure test must be run. Be sure to disconnect the gas supply line from the appliance valve before
pressure testing.
The manifold pressure is pre-set at the factory and should be 3.5" w.c. for Natural Gas and
10" w.c. for L.R Gas. The minimum inlet pressure for Natural Gas is 4.5" w.c. and 11" w.c. for L.R Gas, "for
purpose of input adjustment".
The maximum
inlet pressure should never exceed 7.0" w.c. on Natural Gas or
14" w.c. on L.R Gas.