Irmc S2/S3 Sel Entries Relayed As Sc2 Mib Traps - Fujitsu ServerView Event Manager User Manual

Serverview operations manager v6.12
Table of Contents

Advertisement

iRMC S2/S3 SEL Entries and SC2 MIB Traps
3.7
iRMC S2/S3 SEL entries relayed as
SC2 MIB traps
I
The following table applies to PRIMERGY systems manufactured
in 2009 or later.
If the iRMC S2/S3 writes an event to the System Event Log (SEL), in some
cases an SNMP trap is triggered. The following table shows the correlation
between the iRMC S2/S3 entries in the SEL and the traps they trigger.
I
Not all iRMC S2/S3 entries made in the SEL trigger an SNMP trap. Some
trigger the same trap.
Error
iRMC S2/S3 SEL
code
entry
000011 System event log
(SEL) warning
threshold exceeded
040000 'FAN XY': Fan failed
040001 'FAN XY': Fan is
working
040002 'FAN XY': Fan
prefailure
Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap
28
Trap text
The System Event
Log for cabinet XY at
server XY has
exceeded XY
percent of its
capacity.
Fan 'FAN XY' failed
in cabinet XY of
server XY.
Fan 'FAN XY' was
added into cabinet
XY of server XY.
Fan 'FAN XY' in
cabinet XY of server
XY is working again.
Fan 'FAN XY' will fail
in near future in
cabinet XY of server
XY.
Trap
Trap name
no.
2101 sc2TrapMessa
geLogWarning
2014 sc2TrapFan
Failed
2010 sc2TrapFan
Added
2012 sc2TrapFanOk
2013 sc2TrapFan
Critical