Resetting Alarm Suppression; Deleting Alarms - Fujitsu ServerView Event Manager User Manual

Serverview operations manager v6.12
Table of Contents

Advertisement

I
When the server starts up, a RAID manager or Ethernet card, etc. may
issue an alarm (SNMP trap) as a startup notification (e.g.
RFC1157LinkUP). To suppress this kind of alarm, you can configure
alarm suppression. This function must be specified for each server. If
multiple servers are monitored, configure this setting for each server
using the alarm function.
3.4.3

Resetting alarm suppression

You can reset an alarm suppression that has already been set. Proceed as
follows:
Ê Select Filter Settings from the context menu.
The Reset suppressings window opens, in which all previously set alarm
suppressions are listed. To reset a suppression, proceed as follows:
Ê Select the relevant suppression in the list.
Ê Click the Delete button.
Ê To close the window, click the Close button.
The entry is removed from the list and the alarm setting is active again.
3.4.4

Deleting alarms

To delete alarm entries, proceed as follows:
Ê Select the alarm entries in the list.
Ê Select Delete from the context menu.
I
Alarms with the severity critical cannot be deleted until they have been
acknowledged.
ServerView Event Manager
Processing alarm entries
25