Setting Up Primepower Mib Information - Fujitsu Solaris 10 Hardware Platform Manual

Operating system for primepower series
Table of Contents

Advertisement

7.
Enter the Open Boot Environment. Some of the manuals attached to the card may instruct "Reboot
your machine", which means to enter the Open Boot Environment with the following command.
# /usr/sbin/shutdown -y -g0 -i0 <Return>
8.
When the OK prompt is displayed, boot the system with the following command.
ok boot -r <Return>
For PRIMEPOWER 250/450/650/850/800/900/1000/1500/2000/2500
1.
If the system is running, turn off the power to the system with the following command:
# /usr/sbin/shutdown -y -g0 -i5 <Return>
2.
Install the PCI card to the system. (For more detailed information, refer to the manual attached to
the card.)
3.
Set the MODE switch on the operation panel to "UNLOCK" mode and turn on the power.
4.
After you turn on the power, the OK prompt will be displayed. Boot the system with the following
command.
ok boot -r <Return>
5.
Return the MODE switch on the operation panel to "LOCK" mode.
Some of the PCI cards need driver software. If that is the case, use the following steps:
6.
Add driver software. (For more detailed information, refer to the manual attached to the card.)
7.
Enter the Open Boot Environment. Some of the manuals attached to the card may instruct "Reboot
your machine", which means to enter the Open Boot Environment with the following command.
# /usr/sbin/shutdown -y -g0 -i0 <Return>
8.
When the OK prompt is displayed, boot the system with the following command.
ok boot -r <Return>
On PRIMEPOWER450 (Rackmount Type(7U))/900/1500 (with SPARC64 V)/2500, you are able to use PCI
Hot Plug function, which is included in Enhanced Support Facility. If you use PCI Hot Plug function, refer
to "PCI Hot Plug User's Guide" in Enhanced Support Facility.

1.2.4 Setting Up PRIMEPOWER MIB Information

If you introduce the network management software and want the machine to be monitored using its proper
model name, you have to set up the MIB information as described below.
1.
Log in as a superuser.
2.
Stop the Solstice Enterprise Agent (SEA) daemon.
# /etc/init.d/init.snmpdx stop <Return>
3.
Check the model name with the following command. Note the displayed model name.
# /usr/sbin/FJSVmadm/hrdconf | head -1 <Return>
Example:
PRIMEPOWER400
4.
Modify the /etc/snmp/conf/snmp.conf file.
Before modification:
sysdescr Sun SNMP Agent,
After modification:
sysdescr Fujitsu SNMP Agent, model_name
Write the model name displayed in the step 3, in the place of "model_name".
You can customize the above sysdescr string the way you like. But some network management software
refers to "model-name", please check whether SNMP is running on the system.
6

Advertisement

Table of Contents
loading

Table of Contents