Is the Pad ASSY attached
correctly?
Is the Pad ASSY dirty?
Is the Pad ASSY worn out?
Contact the manufacturer's
authorized service center.
*1) For details on requirements, see "6.2 Document Quality" (page. 87).
*2) For details on double-feed, see "6.5 Double-feed Detection Conditions" (page. 91).
*3) For details on how to clean Pad ASSY, see "3.2 Cleaning the ADF" (page. 43).
*4) For details on how to replace and attach Pad ASSY, see "4.2 Replacing the Pad
76
Continued from previous page
YES
NO
NO
ASSY" (page. 53).
NO
Attach the Pad ASSY
correctly. (*4)
YES
Clean the Pad ASSY. (*3)
YES
Replace the Pad ASSY. (*4)