5. Remove the Pick roller from the shaft while lifting up the tab on the Pick roller.
6. Attach the new Pick roller.
Insert the new Pick roller aligning the protrusion on the shaft with the slot for the screw in
the Pick roller.
Make sure that the Pick roller is completely attached. An incompletely
attached Pick roller might cause document jams or other feed errors.
ATTENTION
When attaching the Pick roller, make sure that the roller clicks in to
place.
Tab
Lift up
Protrusion
Slot
"Click"
fi-4120C Image Scanner Operator's Guide
4.3 Replacing the Pick Roller
Shaft
Pull shaft to remove
4