Cr_Orgmode Command; Cr_Pcstore Command - Sanyo PLC-XF1000 - 12000 Lumens Manual

Rs232 expand serial command
Hide thumbs Also See for PLC-XF1000 - 12000 Lumens:
Table of Contents

Advertisement

PLC-XF1000 Expand Serial Command Functional Specifications

9.5.9 CR_ORGMODE Command

Command
"CR_ORGMODE" [CR]
Get the original signal of current selected Mode that is set in PC Adj.
Details
When MODE1- 10 or EXT11-60 is not selected, get the current signal.
Acceptable
Response
%1
Unacceptable

9.5.10 CR_PCSTORE Command

Command
"CR_PCSTORE" [CR]
Get Free or Stored status of MODE1 - 5 in PC Adjust.
Details
Data consists of 10 bytes and each byte represents MODE1-10.(F:Free, S:Stored)
Acceptable
%1
Response
Unacceptable
"000_%1" [CR]
When input signal is PC Analog;
"VGA1" ------------------------ Indicates signal Is VGA1
"VGA2" ------------------------ Indicates signal is VGA2
:
:
"XGA1" ------------------------ Indicates signal is XGA1
:
:
"WXGA3" --------------------- Indicates signal is WXGA3
"1080I60" --------------------- Indicates signal is 1080i60
"1080I50" --------------------- Indicates signal is 1080i50
"1035I" ------------------------ Indicates signal is 10350i
"720P60" --------------------- Indicates signal is 720p60
"720P50" --------------------- Indicates signal is 720p50
"575P" ------------------------- Indicates signal is 575p
"480P" ------------------------- Indicates signal is 480p
"575I" -------------------------- Indicates signal is 575i
"480I" -------------------------- Indicates signal is 480i
"1080PSF/24" ----------------- Indicates signal is 1080psf/24
"1080PSF/25" ----------------- Indicates signal is 1080psf/25
"1080PSF/30" ----------------- Indicates signal is 1080psf/30
Note; To differentiate between 60Hz and 50Hz in 1080i and 720p,
"60" or "50" is necessary to add to the parameter in this command
* When input signal is not PC Analog, error code "101" is
returned.
"?" [CR]
"000_%1" [CR]
"FFFFFFFFFF" ---------------- ALL Free
"SFFFFFFFFF" --------------- Mode1 is Stored, others are Free
:
"FFFFFFFFFS" --------------- Mode10 is Stored, others are Free
"SSSSSSSSSS" ------------- ALL Stored
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received