Troubleshooting Chart - Campbell Hausfeld FP2200 Series Operating Instructions Manual

Oilless air compressor
Table of Contents

Advertisement

Available languages

Available languages

Oilless Compressors
Troubleshooting Chart
Compressor
will
not
run
1. NO electrical
power
2. Breaker
open
3. Pressure
switch
bad
4. Check
valve
defective
1. Plugged in? Check fuse/breaker
or motor
overload
2. Reset, determine
cause of problem
3. Replace
4. Remove and replace check valve
DO not disassemble check valve
with air in tank; bleed tank
Motor
hums but cannot
run or runs slowly
1. Poor contacts, line voltage
incorrect
2. Shorted
or open motor winding
3. Defective check valve or unloader
1. Check connections,
check with voltmeter
2. Replace motor
3. Replace or repair
DO not disassemble check valve
with air in tank; bleed tank
Fuses blow/circuit
breaker trips repeatedly
[ACAUTION]
Never use an extension
cord with this product
1. Incorrect
size fuse, circuit overloaded
2. Defective check valve or unloader
1. Check for proper
fuse, use time-delay
fuse.
Disconnect
other
electrical
appliances
from circuit or
operate compressor
on its own branch circuit
2. Replace or repair
DO not disassemble check valve
with air in tank; bleed tank
Tank pressure drops
1. Loose connections
(fittings,
tubing,
when compressor
shuts
etc.)
off
2. Loose drain cock
3. Check valve leaking
1. Check all connections
with soap and water solution
and tighten
2. Tighten
3. Disassemble
check valve assembly, clean or replace
DO not disassemble check valve
with air in tank; bleed tank
Air output
lower than
1. Air leaks in piping
(on machine
or in
1. Replace leaking
components
or tighten
as necessary
normaVIow
discharge
outside
system)
pressure
2. Piston ring broken
2. Replace
www.chpower.com