Troubleshooting Chart

Symptom
Possible Cause(s)
Compressor will not
1. No electrical power
run
2. Breaker open
3. Pressure switch bad
4. Motor over worked
5. Tank pressure above cut-in
Fuses blow / circuit
1. Incorrect size fuse, circuit
breaker trips
repeatedly
2. Extension cord usage - wrong
3. Worn check valve
4. Defective unloader valve (on
5. Defective motor capacitor(s)
6. Defective motor
ank pressure drops
1. Loose connections (fittings,
T
when compressor
shuts off
2. Open tank drain valve
3. Tank leaks
4. Worn check valve
Compressor runs
1. Excessive air usage
continuously and / or
air output is lower
2. Clogged intake filter
than normal / low
discharge pressure
3. Open tank drain valve
4. Air leaks in piping (on machine
5. Piston ring worn
6. Broken valve (in pump)
7. Tank leaks
8. Defective pressure switch
xcessive moisture in
1. Excessive water in tank
E
discharge air
2. High humidity
www.campbellhausfeld.com
overloaded
gauge wire and/or too long.
pressure switch)
tubing, etc.)
or in outside system)
Corrective Action
1. Plugged in? Switch on? Check fuse/breaker
2. Reset, determine cause of problem
3. Replace
4. Turn off, let cool, turn on.
5. Bleed tank pressure down to cut-in.
1. Check for proper fuse, use time-delay fuse. Disconnect
other electrical appliances from circuit or operate
compressor on its own branch circuit.
2. Remove extension cord or refer to Extension Cord Chart on
page 4.
3. Replace check valve.
Do not disassemble check valve with
air pressure in tank; bleed tank.
4. Replace unloader valve.
5. Replace capacitor(s)
6. Replace motor
1. Check all connections with soap and water solution.
Tighten; or remove and apply pipe dope or pipe tape to
the threads, then reassemble.
2. Close tank drain valve
3. Check tank for leaks with soap and water solution. If
leak is detected, tank must be replaced with genuine
replacement part.
4. Replace check valve
Do not disassemble check valve with
air pressure in tank; bleed tank.
1. Decrease air usage; compressor not large enough for air
requirement
2. Clean or replace filter
3. Close tank drain valve
4. Check all connections with soap and water solution.
Tighten; or remove and apply pipe dope or pipe tape to
the threads, then reassemble.
5. Replace piston and cylinder.
6. Replace valve
7. Check tank for leaks with soap and water solution. If
leak is detected, tank must be replaced with genuine
replacement part.
8. Replace switch
1. Drain tank
2. Move to area of less humidity; use air line filter