PLC-WXU300 Expand Serial Command Functional Specifications
8.10.14 CF_TERMINAL Command
Command
"CF_TERMINAL_%1"[CR]
"COMPUTER" ----------------Set Input mode
%1
"MONITOR" ------------------- Set Monitor Out mode
Set Terminal setup. This command is available in normal Power ON status.
Details
Terminal means Computer 2 in this model.
Acceptable
Response
Unacceptable
8.10.15 CF_PIP Command
Command
"CF_PIP_%1"[CR]
"OFF" ----------------------------- Set Picture in Picture to OFF
"PINP" ---------------------------- Set Picture in Picture to PinP
"PBYP" --------------------------- Set Picture in Picture to PbyP
"UP" ------------------------------ Switch Mode of Picture in Picture forward
%1
"DN" ------------------------------ Switch Mode of Picture in Picture backward
Select Picture in Picture mode.
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.16 CF_PIPSIZE Command
Command
"CF_PIPSIZE_%1"[CR]
"SMALL" ----------------------------- Select Small
"MIDDLE" --------------------------- Select Middle
"LARGE" ---------------------------- Select Large
"UP" ------------------------------ Switch Subpicture size forward
%1
"DN" ------------------------------ Switch Power management setting
Select Subpicture size of Picture in Picture.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
Details
This command is available in normal Power ON status.
Note) Projector returns "101" by receiving this command when Picture in Picture is
Off.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
When Input is Computer 2, the projector returns "101" and the
command is not executed.
(PinP →PbyP →OFF →PinP...ÿ
(OFF →PbyP →PinP →OFF...ÿ
"000"[CR]
"Error Code"[CR]
(Middle → Large → Small → Middle...ÿ
(Small → Large → Middle → Small...ÿ
"000"[CR]
"Error Code"[CR]
38/72