BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-WM5500
PLC-WM5500L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-WM5500/L - 5500 Lumens

  • Page 1 BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-WM5500 PLC-WM5500L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications Contents 1. Overview..........................5 2. Serial Interface Specification ...................5 2.1. Transfer Specification ....................5 2.2. Connection ........................5 3. Notes for Communication ....................6 4. Functional Execution Command Table................7 5. Status Read Command Table ...................9 6. Functional Execution Command ...................10 Format ........................10 When the command pipelining is needed............10 Transfer Example ....................10...
  • Page 3 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.32 POWER MANAGEMENT CANCEL Command ............16 6.33 POWER MANAGEMENT SHUTDOWN Command ..........17 6.34 D.ZOOM + Command ....................17 6.35 D.ZOOM - Command.....................17 6.36 INPUT 3 VIDEO Command ...................17 6.37 INPUT 3 S-VIDEO Command................17 6.38 INPUT 3 Y,Pb/Cb,Pr/Cr Command ...............17 6.39 POINTER RIGHT Command .................18 6.40 POINTER LEFT Command ...................18 6.41 POINTER UP Command ..................18...
  • Page 4 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications Temp Read Command ..................28 Lamp Mode Read Command ................28 4/28...
  • Page 5: Overview

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 1. Overview 0û These specifications define projector control commands for PLC-WM5500/WM5500 L 0û The projector control commands are used to control a projector through RS-232C from a computer. 2. Serial Interface Specification 2.1. Transfer Specification Item S p e c i f i c a t i o n Synchronous system...
  • Page 6: Notes For Communication

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 3. Notes for Communication 0û The projector command is defined as one command per line that starts with “C” and ends with carriage return (0x0D). 0û When carriage return (0x0D) is received, decoding starts. 0û...
  • Page 7: Functional Execution Command Table

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 4. Functional Execution Command Table Command Command Item Item POWER ON BRIGHTNESS + POWER OFF BRIGHTNESS - (QUICK POWER OFF) POWER OFF INPUT 2 VIDEO INPUT 2 Y,Pb/Cb,Pr/Cr INPUT 1 INPUT 2 RGB INPUT 2 INPUT 3 IMAGE NETWORK...
  • Page 8 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications Command Item Command Item FREEZE ON FREEZE OFF ZOOM - ZOOM + AUTO PC ADJ FOCUS - PRESENTATION TIMER FOCUS + PRESENTATION TIMER (Exit) KEYSTONE ↑ KEYSTONE ↓ INPUT 1 HDMI KEYSTONE → INPUT 1 ANALOG RGB KEYSTONE ←...
  • Page 9: Status Read Command Table

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 5. Status Read Command Table Command Item Note STATUS READ INPUT MODE READ LAMP TIME READ SETTING READ TEMP READ LAMP MODE READ “ ———“ means “No Function”. 9/28...
  • Page 10: Functional Execution Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6. Functional Execution Command 6.1 Format 0û PC issues a command in the following format: “C” Command [CR] Command: two characters (See Functional Execution Command Table) 0û Projector decodes the received data and returns the result when getting ready to receive the next command.
  • Page 11: Operation Requirements

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.4 Operation Requirements 6.4.1 In the following status of projector, Available Functional Execution Commands are limited. Projector Status Available Functional Execution Commands Standby Mode C00: POWER ON C00: POWER ON → Countdown is terminated C01: POWER OFF C02: POWER OFF →...
  • Page 12: Power On Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.5 POWER ON Command Command “C00” [CR] Power ON Detail When already Power is ON, no operation is started. When sending this command during Countdown in process, Countdown is terminated. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 13: Input 3 Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.10 INPUT 3 Command Command “C07” [CR] Select Input 3. This command works differently from the command by “Input 3” key of the remote control. When Input 3 has been selected, this command does Detail not execute the source switching;...
  • Page 14: Sound Mute Off Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.15 SOUND MUTE OFF Command Command “C0C” [CR] Sound Mute Off. Detail This command works the same way as “MUTE” button of the remote control for Sound Mute Off, but does not work for Sound Mute On. Acceptable [ACK] [CR] Response...
  • Page 15: Menu Off Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.21 MENU OFF Command Command “C1D” [CR] Detail Clear On-Screen Display Menu Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.22 DISPLAY CLEAR Command Command “C1E” [CR] Clear On-Screen Display Detail Clear On-screen Display under all conditions Acceptable [ACK] [CR] Response...
  • Page 16: Input 2 Rgb Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.27 INPUT 2 RGB Command Command “C25” [CR] Select RGB input in Input 2. Detail Although projector returns “OK”, Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable [ACK] [CR] Response...
  • Page 17: Power Management Shutdown Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.33 POWER MANAGEMENT SHUTDOWN Command Command “C2E” [CR] Set Power Management function to Shutdown mode. Detail This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 18: Pointer Right Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.39 POINTER RIGHT Command Command “C3A” [CR] Move the Pointer of On-Screen Display Menu to the right. Detail This command works differently from the command by Point button “>” of the projector or remote control and has no “Volume +” function. Acceptable [ACK] [CR] Response...
  • Page 19: Freeze Off Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.45 FREEZE OFF Command Command “C44” [CR] Cancel Freeze mode Detail This command works the same way as “FREEZE” button of the remote control for Freeze Off, but does not work for Freeze ON. Acceptable [ACK] [CR] Response...
  • Page 20: Input 1 Analog Rgb Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.51 INPUT 1 ANALOG RGB Command Command “C50” [CR] Select Analog RGB input in Input 1. Detail Although projector returns “OK”, Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable [ACK] [CR] Response...
  • Page 21: Auto Pc Adj. Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.57 AUTO PC ADJ. Command Command “C89” [CR] Execute AUTO PC ADJ. function Detail This command works the same way as “AUTO PC” button of the remote control. Sending this command during Auto PC Adj. process terminates the operation. Acceptable [ACK] [CR] Response...
  • Page 22: Keystone → Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 6.62 KEYSTONE → Command Command “C90” [CR] Correct keystone distortion by reducing right side of image. This command Detail invokes both operations of keystone distortion correction and OSD display, regardless of whether the “KEYSTONE” OSD has been already displayed or not. Acceptable [ACK] [CR] Response...
  • Page 23: Status Read Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications Status Read Command 7.1 Format 0û PC issues a command in the following format. “CR” Command [CR] Command: one character (See Status Read Command Table) 0û When projector receives an appropriate command, it returns the required data in string. Required Data [CR] Required Data: string (See Status Read Command Table) 0û...
  • Page 24: Status Read Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 7.4 Status Read Command Command “CR0” [CR] Detail Get the projector’s operating status Acceptable “%1” [CR] ”00” = Power ON “80” = Standby “40” = Countdown in process “20” = Cooling Down in process “10”...
  • Page 25 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 0û “10” [CR] Status: Power Failure When the power supply voltage inside the projector reaches abnormal status, the projector is automatically turned off. Abnormal power supply voltage includes; Filter abnormal status Shutter abnormal status The projector returns “10”...
  • Page 26 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 0û “04” [CR] Status: Power Save This indicates it moves to Power-Save status by Power Management function as set in the Setting menu. 0û “21” [CR] Status: Cooling Down in process after OFF due to Lamp Failure When the projector is turned off due to lamp failure, it automatically starts Cooling Down operation.
  • Page 27: Input Mode Read Command

    PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 7.5 Input Mode Read Command Command “CR1” [CR] Detail Get currently selected Input No. Acceptable “%1” [CR] ”1” = Input 1 is selected. “2” = Input 2 is selected. Response “3” = Input 3 is selected. “4”...
  • Page 28 PLC-WM5500/WM5500L Basic Serial Command Functional Specifications 7.8 Temp Read Command Command “CR6” [CR] Get the information of temperature inside a projector. Detail With several built-in temperature sensors, it can get all the temperatures at once. Acceptable “%1 _ %2 _ %3” [CR] %1 = Temp.