Troubleshooting - Amana ABL2222FES0 Use & Care Manual

Bottom freezer refrigerator
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting
Ice
!
i
Refrigerator is
Plastic tubing was used to complete
The manufacturer recommends using copper tubing
leaking water
water connection,
for installation. Plastic is less durable and can cause
leakage. The manufacturer is not responsible
for
property damage due to improper installation
or water connection.
Improper water valve was installed.
Water pressure is low.
Ice forms in inlet
tube to ice maker
Freezer temperature is too high.
Water flow is
Water pressure is low.
slower than normal
Improper water valve was installed.
Check water connection procedure (see pages 8-9).
Self-piercing and 3/,,,saddle valves cause low water
pressure and may clog the line over time. The
manufacturer is not responsible for property
damage due to improper installation or water
connection.
Water pressure must be between 35 to 100 pounds
per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Adjust freezer control (see pages 10-11). Freezer is
recommended to be approximately 0° F (-18 ° C).
Water pressure must be between 35 to 100 pounds
per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Check water connection procedure in your
Installation Instructions. Self-piercing and 3/,,,
saddle valves cause low water pressure and may
clog the line over time. The manufacturer
is not
responsible for property damage due to
improper installation or water connection.
Open water valve completely and check for leaks.
Copper tubing has kinks.
Turn off water supply and remove kinks. If kinks
cannot be removed, replace tubing.
Water filter is clogged or needs to be
Change water filter (see page 17).
changed.
Ice maker is not
Ice maker arm is in OFF position.
Confirm ice maker arm is down. See Automatic Ice
producing ice
Maker, page 16.
Household water supply is not
See Connecting the Water Supply, pages 8-9.
reaching water valve.
Copper tubing has kinks.
Turn off water supply and remove kinks. If kinks
cannot be removed, replace tubing.
Water pressure is too low.
Water pressure must be between 35 to 100 pounds
per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refigerators with water filters.
Check freezer temperature.
See Temperature Controls, pages 10-11. Freezer
temperature should be between 0° to 2° F (-18° to
-17° C) to produce ice.
30

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents