Download Print this page

Kenmore 415.16649011 Use & Care Manual page 34

Liquid propane gas grill

Advertisement

Burner(s) will not
light
using ignitor.
Troubleshooting (continued)
• Faulty electronic
ignition
circuit.
Burner(s) will not
match
light.
Sudden drop in gas
flow or low flame.
Flames blow out.
Flare-up.
Persistent grease
fire.
Flashback...
(fire in burner
tube(s)).
Unable
to fill LP tank.
One burner
does not
light from other
burner(s).
Sparking
somewhere
other than
between
burner and electrode.
See "GAS ISSUES: _ on previous page.
Improper method of match-lighting.
Out of gas.
Excess flow
valve tripped.
Vapor
lock at coupling
nut/LP
tank
connection.
High or gusting winds.
Low on LP gas.
Excess flow valve tripped.
Grease
buildup.
Excessive fat in meat.
Excessive cooking
temperature.
Grease
trapped
by food
buildup
around
burner
system.
Burner and/or
burner
tubes are blocked.
Some dealers have older fill nozzles
with worn threads.
Grease
buildup
or food
particles
in
end(s) of carryover
tube(s).
See Troubleshooting
Integrated
Electronic
Ignition
section.
Inspect
wire insulation
and proper
connections.
Replace
wires if
insulation
is broken.
See "Match-Lighting"
section of Use and Care.
Check for gas in LP tank.
Turn off knobs, wait 30 seconds and light grill. If flames
are still
low, turn off knobs and LP tank valve.
Disconnect
regulator.
Reconnect
regulator
and leak-test.
Turn on LP tank valve,
wait
30 seconds and then light grill.
Turn off knobs and LP tank valve.
Disconnect
coupling
nut from
tank. Reconnect
and retry.
Turn front of grill to face wind or increase
flame
height.
Refill LP tank.
Refer to "Sudden
drop
in gas flow _ above.
Clean burners and inside of grill/firebox.
Trim fat from
meat before
grilling.
Adjust
flower)
temperature
accordingly.
Turn knobs to OFF. Turn gas off at LP tank.
Leave lid in position
and let fire burn out. After grill cools, remove
and clean all parts.
Turn knobs to OFF. Clean
burner and!or
burner tubes. See burner
cleaning
section of Use and Care manual.
The worn nozzles don't
have enough
"bite _ to engage
the valve.
Try a second
LP dealer.
Clean carry-over
tube(s) with
wire brush.
34 ° 464224011