Exhausting The Dryer - GE Profile DPGT750 Owner's Manual And Installation Instructions

Table of Contents

Advertisement

Installation instructions
EXHAUSTING
THE DRYER (cont.)
-A WARNING
USE ONLY METAL
4" DUCT. DO NOT USE
DUCT
LONGER
THAN
SPECIFIED
IN THE
EXHAUST
LENGTH
TABLE.
Ducting
longer
than
150 equivalent
feet will:
• Increase
the drying
times
and the energy
cost.
• Reduce
the dryer
life.
• Accumulate
lint, creating
a potential
fire
hazard.
The correct
exhaust
installation
is your
responsibility.
Problems
due to incorrect
installation
are not
covered
by the warranty.
The length
of the exhaust
system
depends
upon
the type of duct,
number
of turns
and
the type
of exhaust
hood
(wall cap), and all
conditions
noted
below,
Both rigid
and flexible
metal
ducts
are shown
in the table.
For satisfactory
air movement,
the total
duct
length
should
not exceed
150 equivalent
feet.
EXAMPLE ONLY
The following
chart
describes
an example
of
one possible
ductwork
installation,
_J
z
uJ
tm
v
Z a-
._<_
mo
£-4,
.5
h--
EQUIVALENT
RiGiD
NUMBER
EQUIVALENT
DUCT PIECES
LENGTH
X
USED
=
LENGTH
1 Ft.
X
(4)
=
4 Ft.
Rigid
Metal
Ducting
(Preferred)
Elbows
(90°/45 o)
Turns
Less
Than
4 Ft.
Rigid
Ducting
4" Wall
Cap
10 Ft.
X
(3)
2 Ft.
X
(1)
1 Ft.
X
(5)
5 Ft.
X
(1)
30 Ft.
2 Ft.
5 Ft.
5 Ft.
Total Ductwork
Length
=
46 Ft.
TOTAL MUST
BE LESS THAN
OR EQUAL TO 150 FT.
30