Dell 810 Owner's Manual page 29

Owners manual
Hide thumbs Also See for 810:
Table of Contents

Advertisement

Code
Text
E1624 Lost power
supply
redundancy.
Check PSU
cables.
E1626 Power Supply
Mismatch.
PSU1 = ### W,
PSU2 = ### W.
E1629 Power
required >
PSU wattage.
Check PSU and
config.
E1631 System power
draw exceeded
threshold.
Contact
support.
E1632 PowerSafe
event.
Contact
support.
Causes
The power supply subsystem
is no longer redundant. If
the remaining power supply
fails, the system will shut
down.
The power supplies in the
system are not of the same
wattage.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
The processors and memory
throttling is not sufficient to
keep system power
consumption below the
maximum safe level with
current power supply
configuration.
The processors and memory
have been throttled to keep
system power consumption
below the maximum safe
level with current power
supply configuration.
Corrective Actions
See "Troubleshooting
Power Supplies" on
page 167.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system's Getting
Started Guide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
About Your System
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r810

Table of Contents