Code
Text
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
E1210 Motherboard
battery
failure.
Check
battery.
E1211 RAID
Controller
battery
failure.
Check
battery.
E1216 3.3V
Regulator
failure.
Reseat PCIe
cards.
E1222 CPU # VCACHE
Regulator
failure.
Contact
support.
24
About Your System
Causes
Memory exceeded allowable
temperature and has been
disabled to prevent damage
to the components.
CMOS battery is missing or
the voltage is outside the
allowable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
3.3 V voltage regulator
failed.
Processor voltage regulator
failed.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 167. If
the problem persists, see
"Getting Help" on
page 195.
See "Troubleshooting the
System Battery" on
page 166.
Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 130 and
"Troubleshooting System
Cooling Problems" on
page 167.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 177.
Reseat the processor(s).
See "Troubleshooting the
Processors" on page 178.
If the problem persists,
see "Getting Help" on
page 195.