Code
Text
E1313 Fan
redundancy
lost. Check
fans.
E1314 Critical
system
cooling loss.
Check fans
E1410 System Fatal
Error
detected.
E1414 CPU # temp
exceeding
range. Check
CPU heat
sink.
E1418 CPU # not
detected.
Check CPU is
seated
properly.
26
About Your System
Causes
The system is no longer fan
redundant. Another fan
failure would put the system
at risk of over-heating.
All fans have been removed
from the system.
A fatal system error
detected.
Specified processor is out of
acceptable temperature
range.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Corrective Actions
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan"
on page 168.
Ensure that the fans are
properly installed. See
"Troubleshooting a Fan"
on page 168.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 178
and "Troubleshooting
System Cooling
Problems" on page 167.
Ensure that the specified
processor is properly
installed and is as per the
supported configuration.
See Table 3-5 and
"Troubleshooting the
Processors" on page 178.