Optional Floor Stand Installation - Empire Heating Systems SR-10T-3 Installation Instructions And Owner's Manual

Unvented room heater
Table of Contents

Advertisement

4. Mount heater onto the (4) screwheads and complete tightening
the screwheads to the plastic expansion anchors.
Attention! Use the following steps to properly align the upper
louver and the reflector with the heat shield.
a. When replacing upper louver, be sure the bottom lip of
upper louver goes behind the heat shield.
b. When replacing reflector, be sure the top lip of reflector
goes in front of the heat shield.
5. Connect the gas line.

OPTIONAL FLOOR STAND INSTALLATION

1. Align clearance holes on floor stand with screw holes on bot-
tom of heater, as shown in Figure 11.
2. Attach floor stand to heater with (4) screws provided with floor
stand.
3. Connect the gas line.
*Floor stand can not be used in a bedroom installation. SR-10T
must be wall mounted in a bedroom installation.
SR-30T SHOWN
16941-5-0907
Figure 11
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material, other than wood flooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
Attention: Optional Floor Stand meets requirement.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Figure 10