OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)
Wiring
The appliance, when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National Electri-
cal Code, ANSI/NFPA 70, if an external electrical source is utilized
appliance is equipped with a three-prong [grounding] plug for your
protection against shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased, plugged
into the ungrounded receptacle and its wire connected to the receptacle
mounting screw. With this wire completing the ground, the appliance cord
plug can be plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to oil the
blower motor.
Blower Wheel
The blower wheel will collect lint and could require periodic cleaning.
If the air output decreases or the noise level increases, it indicates a dirty
blower wheel.
To clean blower wheel:
1. Turn OFF gas supply to the heater.
2. Turn OFF electrical supply to the heater.
3. Remove lower louver from casing assembly (2 screws).
4. Remove reflector from casing assembly (2 screws).
5. Remove upper louver from casing assembly (2 screws).
6. Clean blower wheel with a vacuum cleaner.
7. As parts are being replaced in reverse order, check for gas leaks at all gas
connections before lower louver is replaced onto casing assembly.
WARNING:
Unplugging of blower accessory will not stop the heater from
cycling. To turn off gas to the unvented heater: Push in gas control
knob slightly and turn clockwise to "OFF." Do not force.
Page 22
.
This
If any of the original wire as supplied with the appliance must be replaced, it must be replaced
with type 125°C wire or its equivalent.
INDEX
PART
NO.
NO.
1
R-2396
2
R-2503
3
R-2395
4
8720161
5
VF-068
6
SR-196
6
SR-198
7
8520141
8
8520142
NOT SHOWN
SR-219
PARTS LIST
DESCRIPTION
BLOWER (INCLUDES MOTOR, FAN, AND
FAN HOUSING)
FAN CONTROL
WIRE ASSEMBLY
BUSHING - HEYCO #SR5KN4
CORD SET ASSEMBLY
BLOWER PAN (SR-18T)
BLOWER PAN (SR-30T)
RUBBER GROMMET (4 REQUIRED)
BRASS BUSHING (4 REQUIRED)
HARDWARE PACKAGE
16941-5-0907