Download Print this page

Emerson 3700 Installation Instructions Manual page 14

Installation instructions for field-mount
Hide thumbs Also See for 3700:

Advertisement

Figure 13. 4-wire cable to Model 3700 – standard core processor
Core processor
terminals
VDC+
(Red)
VDC–
(Black)
Figure 14. 4-wire cable to Model 3700 – enhanced core processor
Core processor
terminals
RS-485A (White)
RS-485B (Green)
VDC– (Black)
VDC+ (Red)
4-wire cable
Maximum cable length:
see Table 1
RS-485B
(Green)
User-supplied or
factory-supplied cable
RS-485A
(White)
4-wire cable
Maximum cable length:
User-supplied or
factory-supplied cable
see Table 1
13
Model 3700 terminals
blue terminal block
(see Figure 11)
16 RS-485B (Green)
15 RS-485A (White)
14 VDC– (Black)
13 VDC+ (Red)
Model 3700 terminals
blue terminal block
(see Figure 11)
16 RS-485B (Green)
15 RS-485A (White)
14 VDC– (Black)
13 VDC+ (Red)