Fireplace Installation - Dimplex DFB8842 Owner's Manual

Hide thumbs Also See for DFB8842:
Table of Contents

Advertisement

Fireplace Installation

Figure 1
31 ⅜" (797 mm)
30 ¼" (768 mm)
For dimensions of the firebox
insert, with and without the trim,
refer to Figure 1. The fireplace
does not require any additional
venting.
!
NOTE 1:
A 15 Amp, 120
Volt circuit is required. A
dedicated circuit is preferred
but not essential in all cases.
A dedicated circuit will be
required if, after installation,
the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating.
Additional appliances on the
same circuit may exceed the
current rating of the circuit
breaker.
8
26 ⅜"
(670
mm)
25 ½"
(648
mm)
Install the fireplace assembly
into the mantel (refer to mantel
assembly instructions).
!
IMPORTANT: If not using a
Dimplex mantel, the firebox
must be installed in an
enclosure with the following
MINIMUM internal/opening
dimensions (Figure 2).
New Wall Construction
1. select a suitable location that
is not susceptible to moisture
and is away from drapes,
furniture and high traffic.
2. Place the fireplace in the
desired location to see how it
will look in the room.
10 ½"
(267 mm)
www.dimplex.com