NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNINg: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
(5) minutes before switching the unit back on. Figure 2 CAUTION: If the unit continuously cuts out, unplug the unit and call customer service at 1-800-DIMPLEX. Button ! NOTE: The heating elements may emit a slight, harmless odor when first used. This odor is a normal...
Use warm water only to clean painted surfaces. Do not use abrasive cleaners on glass surface or spray liquids directly onto any surface. Unit Storage Store the unit when not in use in a dry, dust free location with the power cord properly secured. www.dimplex.com...
LigHT HARnESS REPLACEmEnT Figure 7 Tools Required: Phillips Head Screwdriver CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin. WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.
NOTE: New mounting studs are supplied with the replacement circuit board. Properly orient the new circuit board and reconnect all of the wiring connections. POWER CORD REPLACEMENT Tools Required: Phillips Head Screwdriver CAUTION: If unit was operating prior to servicing allow www.dimplex.com...
at least 10 minutes for lights, heating elements and top Figure 9 panel to cool off to avoid accidental burning of skin. WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons. Open the front control cover.
Replace Light Harness Log set dim, not glowing Burnt out light bulbs Replace light bulbs Flame Shutter Defective Flicker Motor Replace Flicker Motor Light leaking around the log set Log set not positioned properly Check log set for proper fit www.dimplex.com...
Page 11
PROBLeM CAuSe SOLuTION Heater Heater is not turning off Improper operation Refer to Operation Section Defective Heater Switch Replace Heater Switch Defective Thermostat Replace Thermostat Heater is not turning on, but Improper operation Refer to Operation Section flame effect is still functioning Loose wiring Trace wiring in unit Defective Heater Switch...