LOCATINg FIREPLACE
Continued
CAUTION: Do not expose the
heater to the elements (such as
rain, etc.)
CAUTION: Wear gloves and
safety glasses for protection
during installation and main-
tenance.
Plan where to locate and frame fireplace.
Before installation consider the following:
1. Fireplace location must allow for wall and
ceiling clearances (see Installation Clear-
ances).
2. Fireplace screen should not be exposed
to direct sunlight from windows or doors.
3. Unit can be wired for either 120/60 (15
amp circuit) or 240/60 (20 amp circuit).
A dedicated circuit should be provided
to avoid circuit breaker trips or blown
fuses.
Flush Installations are recommended where
living space is limited or at a premium. Since
space required to enclose fireplace would
be located beyond an outside wall, this in-
stallation would require additional planning
and construction. Check local codes for any
restrictions.
Projected Installations can extend any dis-
tance into room. A projection may be ideal for
a new addition on an existing, finished wall.
Corner Installations make use of space
that may not normally be used and provides
a wider and more efficient viewing angle and
heat distribution.
Internal Wall Installations provide a discrete
option for room separation and can also be an
ideal addition to an existing wall.
Internal Wall
Installation
Full Projection
Installation
Figure 3 - Possible Installation Locations
122663-01D
Corner
Installation
Flush
Installation
www.desatech.com
INSTALLATION

INSTALLATION CLEARANCES

Minimum clearances to combustible construc-
tion are:
Top, Back and Sides of Recessed Cabinet 0" Min.
Drywall to Sides of Front Face
Framing at Nailing Flanges
Ceiling to Opening
Floor
Front
Perpendicular Side Wall
Mantel Clearances
For mantel clearances see Figures 4 and 5.
12" Ref.
10
4
/
"
1
2
30°
23"
21"
17"
Note: All Mantel Clearances
are Measured from Top of
Fireplace Opening
Figure 4 - Mantel Clearances
Top View of Fireplace
Safe Zone
5"
30°
Minimum 10"
from Perpendicular
Side Wall
Figure 5 - Mantel Side Clearances
36" Min.
36" Min.
10" Min.
Facing Material May
Be Noncombustible
Wall Treatments or
Combustible Wood
/
"
1
2
Combustible Wood
Mantels and Trims
May Extend Above
1
/
"
1
2
Profile Shown when
Maintained within
30° Parameter
Shown
Framed
Material
Top of Cabinet
15" Min.
Edge of
Firebox
Opening
3"
Combustible
1
/
" Max.
3
4
Material Must
Not Overlap
Front Face
0" Min.
0" Min.
0" Min.
5