INSTALLATION CLEARANCES

Minimum clearances to combustible construction are:
• Top, Back and Sides of Recessed
Cabinet .. . . . . . . . . . . . . . . . . . . . .0" Min.
• Drywall to Sides of Front Face .. . .0" Min.
• Framing at Nailing Flanges.. . . . . .0" Min.
• Ceiling to Opening. . . . . . . . . . . . .36" Min.
Mantel Clearances
For mantel clearances see Figures 3 and 4.
4
INSTALLATION
12" Ref.
4
30°
1
/
"
3
4
16
/
"
5
8
Ref.
13
/
"
3
4
10
/
" Min.
1
2
Note: All Mantel Clearances
are Measured from Top of
Fireplace Opening
Figure 3 - Mantel Clearances
Top View of Fireplace
Safe Zone
5"
30°
Minimum 10" from
Perpendicular Side Wall
Figure 4 - Mantel Side Clearances
www.desatech.com
Continued
• Floor .. . . . . . . . . . . . . . . . . . . . . . .0" Min.
• Front .. . . . . . . . . . . . . . . . . . . . . .36" Min.
• Perpendicular Side Wall .. . . . . . .10" Min.
10
/
"
1
2
Combustible Wood
Mantels and Trims
/
"
1
2
May Extend Above
1
/
"
1
2
Profile Shown when
Maintained within
30° Parameter
Shown
Top of Cabinet
9
/
" Ref.
5
8
3"
1
/
" Max.
3
4
Facing Material May
Be Noncombustible
Wall Treatments or
Combustible Wood
Framed
Material
Edge of Firebox
Opening
Combustible
MaterialMust
Not Overlap
Front Face
111076-01F