IATA — is a special symbology subset of Standard 2 of 5. Enabling IATA
selects this custom code as the active Standard 2 of 5 symbology (superced-
ing any other Standard 2 of 5 features).
Standard 2 of 5 must be enabled before IATA can be enabled.
Enable Codabar — selects Codabar as an active symbology. Allows selection
of Check Digit, Start/Stop character and format, or label format (fixed or
variable length) options.
Enable Code 93 — selects Code 93 as an active symbology. The scanner is preset
to recognize all Code 93 bar codes that have between 2 and 50 characters.
Code 93 has no user-selectable options.
Enable Code 128
is preset to recognize all Code 128 bar codes that have between 2 and 50
characters. Code 128 has no user selectable options.
Enable MSI/Plessey — selects MSI/Plessey as an active symbology. Allows
selection of Check Digit or label format (fixed or variable length) options.
Universal Symbology Selection
To set the scanner to read all symbologies, scan the ENABLE ALL SYM-
BOLOGIES bar code below.
DO NOT scan SET or END bar codes when programming universal
symbology features. Programming mode is automatically entered
and exited when one of the two special bar codes below are
scanned.
1
Code 128 is always active for the purpose of reading programming bar code labels;
however, the scanner does not transmit data to the host when in Programming Mode.
48
NOTE
— selects Code 128 as an active symbology. The scanner
1
NOTE
Enable All Symbologies
Disable All Symbologies