13
CM1000A Wiring Diagram
CON 1
Red : 12v Constant Input
Constant 12-volt (+) positive power input for the control module. This wire
must be connected to a constant 12-volt (+) positive source. The proper wire
will test 12-volt (+) positive with the key in the off position, while key is in the
on position and during crank.
Violet : (+) Parking Light Output
Connect this wire to the (+) positive parking light wire generally at the parking
light switch or behind the fuse box. The proper wire will test 12-volts (+)
positive when the parking light switch is in the on position.
Brown : (+)12v Siren Output
This wire will provide a 30 second (+) positive output for the external siren.
Gray : (+)12v Trunk Output
This wire will provide a (+) positive trigger pulse. (Note: Negative trigger trunk
release will require a relay. System will unlock doors and disarm alarm prior
to trunk release.)
trunk Release Switch
CON1-4
Black : Chassis Ground
This wire will connect to chassis ground. This is one of the most important
connections you will make. Choose a factory grounding point or strip back the
paint before grounding. We do not recommend using the steering column.
Proper grounding is crucial to preventing future problems.
14
trunk
Solenoid