7. Enter a value for the loop ID and press
8. Press
to return to the Configuration Settings menu.
ESC
9. Press
to return to the Fast!UTIL Options menu.
ESC
10. When prompted to save changes made to the current adapter,
select Save Changes and press
11. If there are more adapters to configure, choose Select Host
Adapter, and repeat steps 3 through 11 for each adapter.
12. Press
to exit Fast!UTIL.
ESC
13. Reboot the host.
14. Repeat this procedure on all nodes in the cluster connected to the
CX200-Series array.
15. While you are in the BIOS, you can verify that the topology is set
correctly for direct connect (FC-AL). Follow the instructions
under Setting the Topology for QLA22xx/23xx and Windows on
page 2-13.
CAUTION
!
Future use of the firmware NVRAM file to apply settings will
overwrite and possibly invalidate the changes made above. If you
will later update using a firmware NVRAM file, be sure it is listed
and supports this CX200-Series direct-connect cluster
configuration.
To restore EMC default HBA settings, either reload the approved EMC
NVRAM file, or return to step 5 and ensure that Adapter Hard Loop ID is set
to Disabled.