Hitachi SJ300 Series Replacement Manual page 20

Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

62 Frequency lower limit setting
63 Frequency upper limit setting
64 Jump frequency setting 1
65 Jump frequency setting 2
66 Jump frequency setting 3
67 Jump frequency width setting
68 Allowable instantaneous power failure time
69 Retry wait time before motor restart
Selection of automatic restart mode after
70
instantaneous power failure
71 Voltage trip enable during stop
72 Maximum frequency selection
73 Software lock mode selection
74 STOP key enable
75 Rotational direction restriction
76 Reverse RUN protection enable
77 Analog input selection
78 Analog input active range start frequency
79 Analog input active range end frequency
80 Analog input active range start voltage/current
81 Analog input active range end voltage/current
82 Analog input start frequency enable
83 External frequency filter time constant
84 Frequency arrival signal output method
85 Frequency arrival setting for acceleration
86 Frequency arrival setting for deceleration
87 Over-torque (forward) level setting
88 Over-torque (reverse) level setting
89 Intelligent input terminal 1 function
90 Intelligent input terminal 2 function
91 Intelligent input terminal 3 function
92 Intelligent input terminal 4 function
93 Intelligent input terminal 5 function
94 Intelligent input terminal 6 function
95 Intelligent input terminal 7 function
96 Intelligent input terminal 8 function
No.
Name
setting
Digital
Remote Operator
operator
A6
F-26 LIMIT L
0.0Hz
A5
LOMIT H
0.0Hz
A7
JUMP F1
0.0Hz
A8
JUMP F2
0.0Hz
A9
JUMP F3
0.0Hz
-
JUMP W
0.5Hz
-
F-22 IPS TIME
1.0s
-
IPS WAIT
1.0s
A34
IPS POWR
ALM
-
IPS TRIP
OFF
A64
F-30 F-MAX-L
120Hz
-
F-25 S-LOCK
MD1
-
F-28 STOP-SW
ON
-
F-29
F/R SW
FRE
-
F/R PREEV
OFF
A48
F-31 IN ANA
10V
A26
IN EXS
0.0Hz
A27
IN EXE
0.0Hz
-
IN EX%S
0%
-
IN EX%E
100%
-
IN LEVEL
0Hz
A11
IN F-SAMP
8
A49
F-32 ARV PTN
CST
A39
ARV ACC
0.0Hz
A40
ARV DEC
0.0Hz
-
F-33 OV-TRQ V
100%
-
OV-TRQ R
100%
C0
F-34
IN-TM 1
RS
C1
IN-TM 2
AT
C2
IN-TM 3
JG
C3
IN-TM 4
FRS
C4
IN-TM 5
CH1
C5
IN-TM 6
CF2
C6
IN-TM 7
CF1
C7
IN-TM 8
REV
J300
Function code
Default
21/24
code
(Digital
operator)
A value for the second motor can be set independently by
A062
0.00
A262 in the case of the SJ300.
A value for the second motor can be set independently by
A061
0.00
A261 in the case of the SJ300.
A063
0.00
A065
0.00
A067
0.00
Note
0.50
Note: Jump frequency width setting: A064, A066, and A068
b002
1.0
b003
1.0
b001
00
b004
00
-
-
No need to set in the case of the SJ300
b031
01
b087
00
b035
00
b046
00
Note
-
Note: Please adjust with analog input setting functions
Note
0.00
Note: (SJ300) O: A011, OI: A101, O2: A111
Note
0.00
Note: (SJ300) O: A012, OI: A102, O2: A112
0(O), 20(OI),
Note
Note: (SJ300) O: A013, OI: A103, O2: A113
-100(O2)
Note
100
Note: (SJ300) O: A014, OI: A104, O2: A114
Note
01(0Hz)
Note: (SJ300) O: A015, OI: A105
A016
8
Note: Selection from FA1 to FA5 at an intelligent output
Note
-
terminal
C042(045)
0.00
C043(046)
0.00
Note: Forward-driving/reverse-regenerating can be set
C055/C056
100
independently in the case of the SJ300.
Note: Reverse-driving/forward-regenerating can be set
C057/C058
100
independently in the case of the SJ300.
C001
18(RS)
C002
16(AT)
C003
06(JG)
C004
11(FRS)
C005
09(2CH)
03(CF2)(CE
C006
ver.)/13(USP)(UL
ver.)
C007
02(CF1)
C008
01(RV)
SJ300
Function
Default setting
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

J300 series

Table of Contents