No.
Name
1 Frequency source setting
2 Run command source setting
3 Data command method
4 Initialization mode (parameters or trip history)
5 Debug mode enable
6 Keypad RUN key routing
7 Reset mode selection
8 Base frequency setting 1
Base frequency setting 2
9 Maximum frequency setting 1
Maximum frequency setting 2
10 Start frequency adjustment
11 AVR voltage select
12 AVR function select
13 V/f characteristic curve selection 1
V/f characteristic curve selection 2
14 Auto-tuning setting
15 Motor data selection 1
Motor data selection 2
16 Motor capacity setting 1
Motor capacity setting 2
17 Motor poles setting 1
Motor poles setting 2
18 Motor constant R1 1
Motor constant R1 2
19 Motor constant R2 1
Motor constant R2 2
20 Motor constant L 1
Motor constant L 2
21 Motor constant M 1
Motor constant M 2
22 Motor constant J 1
Motor constant J 2
23 Speed response proportional constant Kp 1
Speed response proportional constant Kp 2
24 Option constant Ti 1
Option constant Ti 2
Option constant Kpp 1
Option constant Kpp 2
25 Carrier frequency setting
No.
Name
J300
Function code
Default
Digital
setting
Remote Operator
operator
F9
F-SET-SELCT
REM
F9
F/R-SELCT
REM
-
F-09 PARAM
REM
-
F-38 INIT TCNT
CNT
-
INIT DBGU
OFF
F4
INIT DOPE
FWD
A86
INIT RESET
ON
A62
F-00 F-BASE
60
A62
F-BASE
60
A63
F-01 F-MAX
60
A63
F-MAX
60
A4
F-02 F-min
0.5
F11
F-03 AVR AC
200/400
-
AVR AC
ON
A0
F-04 CONTROL
VC
A0
CONTROL
VC
A97
F-05 AUX AUTO
NOR
A98
AUX DATA
TMO
A98
AUX DATA
TMO
A1
AUX K
Factor set
A1
AUX K
Factor set
A2
AUX P
4
A2
AUX P
4
-
AUX R1
Factor set
-
AUX R1
Factor set
-
AUX R2
Factor set
-
AUX R2
Factor set
-
AUX L
Factor set
-
AUX L
Factor set
-
AUX M
Factor set
-
AUX M
Factor set
-
AUX J
Factor set
-
AUX J
Factor set
A3
AUX Kp
2.00
A3
AUX Kp
2.00
-
AUX Ti
100ms
-
AUX Ti
100ms
-
AUX Kpp
1.00
-
AUX Kpp
1.00
A10
F-36 CARRIER
Factor set
J300
Function code
Default
19/24
SJ300
Function
code
Default setting
(Digital
operator)
A001
02
A002
02
C070
02
b084
00
C091
00
F004
00
C102
00
A003
60
A203
60
A004
60
A204
60
b082
0.50
A082
200/400
A081
00
A044
00
A244
00
H001
00
H002
00
H202
00
H003
Factor set
H203
Factor set
H004
4
H204
4
H020
Factor set
H220
Factor set
H021
Factor set
H221
Factor set
H022
Factor set
H222
Factor set
H023
Factor set
Io is set in the case of the SJ300.
H223
Factor set
H024
Factor set
H224
Factor set
H050
100.0
Motor proportional gain constant setting in the case of the
SJ300.
H250
100.0
H051
100.0
Motor integral gain constant setting in the case of the SJ300.
H251
100.0
H052
1.00
H252
1.00
b083
Factor set
Please refer to 4.3 Carrier Frequency.
SJ300
Function
Default setting
Remarks
Remarks