Chapter 4 - Parameter Setting
If the current setting values of the J300 are different form the SJ300 default setting value, you need to change the setting.
Please refer to the following for comparison.

4.1 Monitoring functions

No.
Name
1 Output frequency setting
Multi-speed frequency setting
2
3 Output frequency setting
4 Jog frequency setting
5 Option 1 setting frequency
6 Option 2 setting frequency
7 Output frequency monitor
8 Acceleration time setting 1
Acceleration time setting 2
9 2-stage acceleration time setting
10 Deceleration time setting 1
Deceleration time setting 2
11 2-stage deceleration time setting
Motor pole number setting for rotation speed
12
monitor
13 Motor rotation speed monitor
14 Frequency scaling conversion factor
15 Scaled output frequency monitor
16 Output current monitor
17 Output current proportion monitor
18 Torque monitor
19 Manual torque boost value 1
Manual torque boost value 2
20 Manual torque boost frequency adjustment 1
Manual torque boost frequency adjustment 2
21 V/f gain setting
22 Jog frequency setting
23 FM terminal analog meter adjustment
24 Intelligent input terminal monitor

4.2 Function mode

J300
Function code
Default setting
Digital
Remote
operator
Operator
F2
FS
000.0
F2
1S
0.0
F2
7S
0.0
F2
TM
0.0
F2
JG
1.0
F2
O1
0.0
F2
O2
0.0
d0
FS
0.00
F6
ACC1
30.0
F6
ACC1
30.0
F6
ACC2
15.0
F7
DEC1
30.0
F7
DEC1
30.0
F7
DEC2
15.0
A25
RPM_
4
d1
_RPM
0
A47
/Hz_
1.0
d3
/Hz_
0.00
d2
Im_
0.00
-
Im_
0.0
-
Torque
0
F8
V-Boost Code
11
F8
V-Boost Code
11
-
V-Boost F
10
-
V-Boost F
10
-
V-Gain
100
A61
Jogging
1.00
F10
ADJ
172
-
TERM
LLLLLLLLL
18/24
SJ300
Function
code
Default setting
(Digital
operator)
F001
0.00
Can be set also by A020 in the case of the SJ300
A021
0.00
A027
0.00
F001
0.00
Jogging stop mode can be selected by A039 in the case of
A038
1.00
the SJ300.
F001
0.00
F001
0.00
d001
0.00
F002
30.00
F202
30.00
A092
15.00
F003
30.00
F203
30.00
A093
15.00
-
-
Not supported by the SJ300; substitutable with b086
-
-
Not supported by the SJ300; substitutable with d007
b086
1.0
d007
0.00
d002
0.00
Not supported by the OPE-J (J300); not supported by the
-
-
SJ300
d012
0.0
Not supported by the OPE-J (J300)
A042
1.0
Voltage level is equivalent although the default settings are
different between J300 and SJ300.
A242
1.0
A043
5.0
The SJ300 has the different default setting (5%) from that
(10%) of the J300.
A243
5.0
A045
100
Jogging stop mode can be selected by A039 in the case of
A038
1.00
the SJ300.
AM and AMI terminals can be also adjusted independently in
b081
60
the case of the SJ300.
Note: Displayed by the 4-digit display; intelligent output
d005
Note
terminal monitor is also supported by d006.
Remarks