Specifications - Lightolier WES SERIES 2X4 Specification

Cleanguard wet location

Advertisement

CLEANGUARD WET LOCATION
Page 2 of 2
PHOTOMETRY
ORDERING INFORMATION
Explanation of Catalog Number. Example: WES2GFSVA432120O4GLR
WE
S
2
CLEANGUARD
FIXTURE
WIDTH
WET
LOCATION
STATIC
OPTIONS & ACCESSORIES
SPECIAL LENSES: Substitute VI for VA (standard) .125" nominal pattern 12
with 6.8 oz. average weight per square foot.
PLASTER FRAME: Catalog number: PF24.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges
are required between fixtures. Order Catalog Number: S2FCTRIM (each joint).
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture
is standard. SUFFIX: RF.
FUSING:
Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
ELECTRICAL/WIRING OPTIONS: Consult factory.
DRYWALL KIT: Order Catalog Number: FK92X4. Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than .85. To prevent glare the VCP shall be not less than 43 either length-
wise or crosswise (at 100fc level) and the average brightness at 65° shall not
exceed 3108 candelas per square meter. To control veiling reflections, luminaire
output in the 30°-90° zone shall not be less than 68.6%.
2' x 4' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE
MODEL NO. WES2GFSVA432
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
visual comfort probability (rated lumens per lamp 3150.)
LENS FRAME:
FS= Flat steel frame
RA=Regressed
aluminum frame
FA=Flat aluminum
frame
CEILING TYPE:
LENS/SHIELDING TYPE:
G= Grid (lay-in T bar)
VA (virgin acrylic)
F=Flanged (overlap) Z spline
standard (see options and
and plaster frame
consult factory)
WES SERIES 2X4
LER = FL - 73.2
IW - 108.7
Comparative yearly lighting energy cost per 1000 lumens = $3.28
RF
20
RC
80
RW
70
50
30
1
89
85
82
2
82
75
70
3
75
67
61
4
69
60
53
5
64
54
47
6
59
49
42
7
55
44
37
8
51
40
34
9
48
37
31
10
45
34
28
room size
ceiling height
W
L
8.5
10.0
13.0
20
20
57
62
69
20
30
49
54
59
20
40
45
49
54
20
60
41
45
49
30
20
59
63
68
30
30
50
54
58
30
40
45
49
52
30
60
41
44
47
30
80
39
42
43
40
20
61
65
69
40
30
52
56
59
40
40
47
50
53
40
60
42
45
47
40
80
39
42
43
40
100
38
40
41
60
30
54
58
60
60
40
48
51
53
60
60
43
45
47
60
80
40
42
43
60
100
38
40
40
100
40
51
54
56
100
60
46
48
49
100
80
42
44
44
100
100
40
42
42
LAMP
QUANTITY:
2=2 Lamp
3=3 Lamp
4=4 Lamp
LAMP/
FIXTURE LENGTH:
32=T8
34=T12
(Nominal 48")
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing with side rails hemmed over and housing ends turned-in for
safe handling.
FINISH: Chassis exterior—black baked polyester enamel. Cavity—white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female
cones, running 45° to the panel edge, .095" nominal thickness (similar to pat-
tern 12). VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per
square foot.
ELECTRICAL: Thermally protected class "P" ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.
Job Information
Lightolier
a Genlyte Thomas Company
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
2, 3 OR 4 LAMP, T8 OR T12
BF - 0.86
20
20
50
30
50
30
10
50
30
80
78
76
77
75
71
67
64
68
65
63
58
54
61
57
57
51
47
55
50
51
45
41
50
44
46
41
36
45
40
42
36
32
41
36
39
33
29
38
33
36
30
26
35
30
33
28
24
32
27
ceiling height
16.0
8.5
10.0
13.0
16.0
77
57
60
67
75
66
52
54
58
64
59
49
51
54
57
54
46
49
51
54
75
59
62
66
73
64
53
55
57
62
56
49
51
53
55
51
46
48
49
52
47
44
46
47
50
74
61
64
68
73
64
54
57
59
62
56
50
52
54
56
50
46
49
49
51
46
44
47
47
49
44
43
45
46
47
64
55
58
59
63
57
51
53
54
56
50
47
49
49
51
46
44
46
47
49
43
43
45
45
47
59
53
55
56
59
53
49
51
51
53
48
46
48
48
50
44
44
46
46
47
OPTIONS:
VOLTAGE:
Add appropriate suffix to
120 or 277
catalog no., ie: (GLR)
BALLAST TYPE:
1 & 2 Lamp Mag. T12
LE
2-2 Lamp Mag. T12
LE
<
<
20THD
10THD
I
1 & 2 Lamp Elec. T8
SO*
H
*
I
2-2 Lamp Elec. T8
SO*
H
*
1-3 Lamp Elec. T8
O3*
H3*
1-4 Lamp Elec. T8
O4*
H4*
LOL T8 Dimming
PS
*Instant Start Standard
Other dimming options. Consult factory.
Type:
www.lightolier.com
SECTION 6/Folio N30-12
10
73
62
53
46
41
36
32
29
26
24