APPENDIX C: PHOENIX AND EN3 CABLE ASSEMBLY
2. Insert the five exposed conductors, from one end of the cable, into the five cable holes in one of the Phoenix connectors.
Use the following wiring scheme.
Side (cable attached)
Phoenix 5-Pin Female Cable Mount Connector
3. Secure the conductors by tightening the five screws in the Phoenix connector.
4. Repeat the previous steps and attach the other end of the cable to the other Phoenix connector.
5. Verify the wiring polarity is correct for both connectors.
48
Pin #1
Pin #2
Pin #3
Pin #4
Pin #5
Tighten screws
Black
48 V DC (–)
Red
48 V DC (+)
Shield
Audio shield
Blue
Audio (–)
White
Audio (+)
Connector side up