Overview; Cleaning; Service Maintenance - Epson Stylus C82 Service Manual

Color inkjet printer
Hide thumbs Also See for Stylus C82:
Table of Contents

Advertisement

EPSON Stylus C82

6.1 Overview

This section provides information to maintain the printer in its optimum condition.

6.1.1 Cleaning

This printer has no mechanical components which require regular cleaning except the
Printhead. Therefore, when returning the printer to the user, check the following parts
and perform appropriate cleaning if stain is noticeable.
Never use chemical solvents, such as thinner, benzine, and
acetone to clean the exterior parts of printer like the housing.
These chemicals may deform or deteriorate the components of
the printer.
Be careful not to damage any components when you clean inside
the printer.
Do not scratch the surface (coated part) of PF roller assembly.
Use soft brush to wipe off any dusts. Use a soft cloth moistened
with alcohol to remove the ink stain.
Exterior parts
Use a clean soft cloth moistened with water and wipe off any dirt. If the exterior
parts are stained with ink, use a cloth moistened with neutral detergent to wipe it
off.
Inside the printer
Use a vacuum cleaner to remove any paper dust.
ASF LD Roller
When cleaning ASF internal rollers with an adhesive surface cleaning sheet, after
setting the cleaning sheet, press the Paper Feed switch while pressing on the paper
with one hand. Because this printer is a 2 roller type (LD Roller and Retard
Roller), perform cleaning a second time with the adhesive surface of the cleaning
sheet facing rearward.
MAINTENANCE

6.1.2 Service Maintenance

If print irregularity (missing dot, banding, etc.) has occurred or the printer indicates
"Maintenance Error", take the following actions to clear the error.
Head Cleaning:
4 methods of recovering Dot Missing are shown below.
1.
Press Ink Switch on control panel.
2.
Execute cleaning with printer driver.
3.
Execute strong cleaning with Adjustment Program.
4.
Execute Ink Charge with Adjustment Program.
Maintenance Error Clear:
Maintenance errors cannot be cleared from the control panel, which is different
from previous models. They can only be handled by the Adjustment Program. (See
"Chapter 5 Adjustment" for details.)
Overflow Counter Limit:
Overflow Counter (Protection Counter) >= 44436
Timing for Replacing the Waste Ink Pad:
By checking the accurate Protection Counter with the Adjustment Program,
the recommended replacement time for a new Waste Ink Pad can be seen.
(See "Chapter 5 Adjustment" for details.)
After the Replacement:
Clear the Overflow Counter (Protection Counter):
The Protection Counter can only be cleared with the Adjustment Program.