Environmental Conditions

1.2.5
Table 1-6. Requirements for Operation and Storage
Description
Temperature
Humidity
Resistance to shock
Resistance to vibration
Note:
*2= When the pnnteris in the shipping container.
*3= Without condensation.
Humidity
80%

Figure 1-6. Temperature/ Humidity Range

1.2.6 Electrical Specifications

Item
Rated voltage
Input voltage range
Rated frequency range
Input frequency range
Rated current
Power consumption
Insulation resistance
Dielectric strength
Rev. A
Operating
10- 35° C (50 - 95° F)*
20- 80% RH "
1 G, within 1 ms
0.15 G, 10-55 Hz
c
10"
27" C
F)
(80" F)
Table 1-7. Electrical Specifications
120 V Version
120 VAC
103.5- 132 V
50-60 Hz
49.5 -60.5 Hz
0.5 A
(self-test with 10 cpi LQ
characters)
10 MQ, minimum
(applying 500 VDC between AC
line and chassis)
1000 VAC rms -1 minute or
1200 VAC rms -1 second
(between AC line and chassis)
Storage
l
-20- 50° c (-4 - 122° F)
1
3
'"
5- 85% RH '
2 G, within 2 ms 2
0.50 G, 10-55 Hz
Print assured range
c
"c
35"
(95" F)
("F)
220-240 V Version
220-240 VAC
198-264 V
50-60 Hz
49.5 -60.5 Hz
(self-test with 10 cpi LQ
characters)
10 MQ, minimum
(applying 500 VDC between AC
line and chassis)
1500 VAC rms -1 minute
c
2
2
"3
2
0.3 A