5.3.2 Temporary Changes in a Step

5.3.3 Saving Changes in the Program

5.3.4 Deleting a Program

24
Every function in a step can be changed as required. This change
applies only for this program run. When the step is exited these
changes are lost. Parameter changes can also be made.
Press the key for the desired fullness value.
The new fullness value appears in the left display.
When the program is run again the original value is activated
again.
If the program is to be changed permanently, proceed as follows :
Select the step to be altered.
Hold down the "Y" key and tap the "P" key.
The controls change to the editing mode.
The decimal points in the step display blink.
Example
Enter a new fullness value.
If desired, enter further parameters, such as e.g. supplementary
thread tension.
Hold down the "Y" key and tap the "P" key.
The complete program is saved.
The program continues with the altered step.
Or
Press the "E" key.
The program is mirrored to the other sleeve side,
If an active program is to be deleted, this is possible with the following
key entries :
Hold down the "Y" key and tap the "P" and "E" keys.
The keys must be held for 2 seconds, then the program number
goes out. After the release of all keys, the controls branch to the
program number entry.
The program number display blinks.
A new program number can be entered.
Note:
The deleting of a program is only possible in a program which is not
running.