Diagnostic Error Code
030-196-XXX SCSI interface test halt, error threshold
exceeded
030-197-XXX SCSI interface test warning
030-198-XXX SCSI interface test aborted
030-199-XXX SCSI interface test failed, cause unknown
035-000-XXX RAID interface Test Passed
035-0XX-XXX RAID interface Failure
035-195-XXX RAID interface Test aborted by user
035-196-XXX RAID interface test halt, error threshold
exceeded
035-197-XXX RAID interface test warning
035-198-XXX RAID interface test aborted
035-199-XXX RAID interface test failed, cause unknown
071-000-XXX Audio port Interface Test Passed
FRU/Action
1. Press F3 to review the log file.
2. Re-start the test to reset the log file.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility program" on page 39.
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility program" on page 39.
2. Flash the system and re-test. See "Updating
(flashing) the BIOS from a disc" on page 261.
3. Go to "Undetermined problems" on page 64.
1. Go to "Undetermined problems" on page 64.
2. Flash the system and re-test. See "Updating
(flashing) the BIOS from a disc" on page 261.
3. Replace component under function test.
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed.
4. System board
Information only Re-start the test, if necessary.
1. Press F3 to review the log file.
2. Re-start the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility program" on page 39.
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility program" on page 39.
2. Flash the system and te-test. See "Updating
(flashing) the BIOS from a disc" on page 261.
3. Go to "Undetermined problems" on page 64.
1. See "Undetermined problems" on page 64.
2. Flash the system and re-test. See "Updating
(flashing) the BIOS from a disc" on page 261.
3. Replace component under function test.
No action
Chapter 7
.
Symptom-to-FRU index
55