2.14.4 Stroke Movement of the Transporter
4
34
When the needle point reaches the stitch hole then the downward
moving tooth tip of the
transporter should be at the same height as the stitch bed surface.
Caution Risk of Injury!
Turn off main switch before adjusting.
–
Remove the grease cap and oil baffle.
–
Arrest the machine in position B.
–
Turn the stroke eccentric 4 so that, in the direction of rotation, the
1st screw is level with the 2nd screw of the thrust eccentric.