Needle Bar Link; General Information - Duerkopp Adler 195 Service Manual

Hide thumbs Also See for 195:
Table of Contents

Advertisement

2.3

Needle Bar Link

2.3.1

General Information

1
10
The 195 is equipped with a split needle bar link.
The fixed part of the needle bar is screwed directly to the cast body.
The second part with the transport foot bar is attached moveably.
The screw 1 with yellow paint and secured against turning with
adhesive must lie on in the arm.
The guide bolt 2 (in the link) and the right hand guide bolt 3 in the arm
have been set at the factory so that the link moves easily with no play.
The positions of the two guide bolts must not be altered.
2
3