TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION
IMPORTANT
The Installer Setup Menu (Table 4) shows all the available options. These options customize themselves as
you make selections to the Installer Setup. Therefore, not all Installer Setup Selections are shown or are avail-
able to change.
Installer
Setup
Select
Number
Not used.
1 thru
0099
Date (Year
0120
Upper)
Date (Year
0130
Lower)
Date (Month) 0140
Date
0150
(Day)
Schedule
0160
Options
System Type
0170
Selection
Fan Operation 0180
Backup Heat
0200
Source
(Auxiliary
Heat)
External
0210
Fossil Fuel Kit
Cycles per
0220
hour (cph) for
1st Stage
Compressor
Cycles per
0230
hour (cph) for
2nd Stage
Compressor
Pub. No. 18-HD25D19-3
69-1790—3
Table 4. Installer Setup Menu.
Factory Setting
Option
Description
20
Set first two digits of
current calendar year
(20 for year 2005, etc)
05
Represents last two
digits of current
calendar year (2005).
6
Digit(s) represents
current calendar
month.
15
Digit(s) represents
current calendar date.
4
7-day programming
1
1 Heat/1Cool
0
Heat/Cool
applications where
equipment controls
fan operation in heat
mode.
0
Heat pump backup
heat source is electric.
1
External fossil fuel kit
is controlling heat
pump backup heat
(recommended)
3
Compressor Stage 1
cycles per hour (cph)
3
Compressor Stage 2
cycles per hour (cph)
Other Choices
Options
Description
21
21 —first two digits of current
calendar year (21xx)
00 -99
Select last two digits of current
calendar year.
1-12
Select number that represents
current calendar month.
1-31
Select number that represents
current calendar date.
0
0—nonprogrammable
1-12
1—1heat/1cool
2—single-stage heat pump (no
aux. heat)
3—heat only (no fan)
4—heat only (with fan)
5—hot water Series 20 (3-wire
or normally open zone valves)
6—cool only
7—2 heat/1cool heat pump
8—2 heat/2 cool
9—2 heat/1cool
10—1 heat/2 cool oil furnace
or 0H/2C
11—2 heat/2 cool heat pump
(with no auxiliary heat)
12—3 heat/2 cool heat pump
(with auxiliary heat)
1
Heat pump or electric heat
applications where comfort
control controls fan operation
in heat mode.
1
Heat pump backup heat
source is fossil fuel.
0
No external fossil fuel kit is
controlling heat pump backup
heat. This comfort control
controls the backup fossil fuel
heat with outdoor sensor.
1-6
1-6 available;
3 is recommended.
1-6
1-6 available;
3 is recommended.
12
Comments
2000 - 2178 available
2000 - 2178 available
Available options and
defaults vary by
comfort control.
System selection
automatically
modifies some
default settings and/
or hides other
Installer Setup
options.
Only shown if heat/
cool system is
selected. If heat
pump is chosen, fan
defaults to electric.
Only shown if 2 heat/
1 cool or 3 heat/2
cool heat pump is
chosen.
Only shown if fossil
fuel is chosen as
backup heat source.
Only shown if two
stages of cool are
selected.