Installer Setup Standard Settings; Advanced Settings - Equipment; Advanced Settings - Accessories - Trane 824 Comfort Control Installation Manual

Works with nexia home intelligence
Table of Contents

Advertisement

5.3.4 Group 4 Accessories Settings
MENU ITEM
Filtration Type Installed
Humidifier Installed
Humidifier - Select Relay Panel Aux Contact
Humidifier Type
Humidifier Control
Humidifier Fan Action
Airflow During Humidifier Only Mode
UV Light Installed
Dehumidifier Installed
Dehumidifier - Select Relay Panel Aux
Contact
Dehumidifier Control Options
Run System Fan with Dehumidifier Request
Outdoor Temperature Ventilation Override
Ventilation - Minimum Outdoor Temperature
Ventilation - Maximum Outdoor Temperature
Minimum Ventilation Runtime
Acculate Overridden Runtime
Acculate Period
18-HD72D1-1
OPTIONS [DEFAULT] DESCRIPTION
Air Cleaner,
Select the filter type installed
[Media Filter]
[None], Yes
Select whether a humidifier is installed
[Aux 1], Aux 2
Select which set of Aux contacts is connected to the humidifier
[Powered/Bypass], Steam
Select what type of humidifier is installed
Select how the humidifier will be controlled (Outdoor temperature
[RH Control], Frost Control
sensor must be connected and enabled to allow this setting to be
selected)
[Humidify with Active Heat
Select when the humidifier is allowed to operate (Humidification is
Call], Humidify without
disallowed during cooling mode or when the System Mode is Auto but
Active Heat Call
the last call was cooling)
Select the desired airflow when the humidifier is operating without an
35% - 100% [50%]
active call for heat
[None], Yes
Select whether a UV Light is installed
[None], Yes
Select whether a ventilation system is installed
Aux 1, [Aux 2]
Select which set of aux contacts is controlling the ventilation system
[Stand Alone Operation],
With Active Call for Cooling
Only
Yes, [No]
Select whether an outdoor temperature override is allowed (Outdoor
[Disable], Enable
temperature sensor must be connected and enabled to allow this
setting to be selected)
*-10°F - 50°F [0°]
Select the minimum outdoor temperature that ventilation is allowed
80°F - 110°F [100°F]
Select the maximum outdoor temperature that ventilation is allowed
0 - 60 Minutes [5 Minutes]
Select the minimum runtime per hour for ventilation system
[No], Yes
Select whether the overridden ventilation runtime will be made up
[4 hours -recover
only when outdoor
conditions are favorable],
24 hours - recover
Select when to recover missed ventilation runtime due to outdoor
only when outdoor
conditions exceeding the minimum/maximum outdoor temperate for
conditions are favorable,
ventilation (The first two options will not meet AHRAE 62.2 standard for
4 hours - recover as
minimum ventilation requirements)
need to meet minimum,
24 hours - recover as
needed to meet minimum
824 Programmable Comfort Control
page 23